Computed Tomography Services

HESCO Home


  
  

Computed Tomography Services  

X-Ray Inspection
X-Ray Manufacturing
Computer Tomography Services
About Us
White Papers
Frequently Asked Questions
Contact Information


  



Deepscan Operations
HESCO and CITA SYSTEMS, INC. have joined forces in an application-driven strategic alliance: v DeepScan Operations

The new joint-venture is the technology partner to the new Deepscan Consortium, which includes the world’s largest offshore oil & gas production companies.

HESCO and CITA have been chosen to supply DeepScan Consortium with Phase 1 R&D services, including High Energy X-ray CT scanning with the CITA 201 System. Phase 2 will include production of CT Systems for in-service inspection of flexible risers sub-sea, at depths of several kilometers.

Why HESCO and CITA Systems?
HESCO and CITA Systems offer the best High Energy X-ray & CT/DR technology for the task at hand, because DeepScan Operations is the world’s only manufacturer of both linacs and CT/DR systems, and provider of High Energy X-ray NDT services - all under one roof - and is uniquely qualified to take on the DeepScan challenge.

CITA 201 System
CITA 201 System




R&D/PRODUCTION NDE OF CRITICAL PATH AEROSPACE ASSEMBLIES
R&D/Production NDE Of Critical
Path Aerospace Assemblies


Volumetric Flaw Detection in Complex Castings and Assemblies
Volumetric Flaw Detection in
Complex Castings and Assemblies


REVERSE ENGINEERING/PROTOTYPE  DESIGN/FAILURE ANALYSIS NDE
Reverse Engineering/Prototype
Design/Failure Analysis NDE



HESCO-CITA Model 201 CT Scanner Performance Specifications

Performance Factor Specification
Operation Modes Preview Scan, Digital Radiograph, Computed Tomography, Density Projection Automatic Calibration, Fault Isolation, Self-diagnostics
Object Weight 0 to 2500 pounds
Object Space Envelope 60 inch diameter x 72 inch high
Maximum Object Penetration Steel – 10 inches (254 mm)
Aluminum – 29 inches (736 mm)
Rubber, Plastic, Wood – 45-100 inches
(1150 to 2500 mm)
Slice Thickness at Object .5mm to 10mm
Defect Detection 6.0 uin3 (0.1 mm3)
High Contrast Inclusion 6.0 uin3 (0.1 mm3)
Crack Detection 1.0 mil (.025mm)
Spatial Resolution
Typical High 10 mils (.25mm)
Typical Medium 40 mils (1.0mm)
Dimensional Accuracy 1.0 to 5.0mils (0.025 to 0.13mm)
Time-Data Acquisition and Image Reconstruction Object/Resolution Dependant
(Example – Aluminum cylinder 8 inch diameter) 10 minutes – high resolution
3 minutes – medium resolution
Image Array Dimension As large as required
Total Acquisition and Reconstruction 10.0 minutes – high resolution
6.0 minutes – medium resolution
Dynamic Range of Count Rate 1 to 2.5 x 107 Hertz
Measurement Absolute Density
Absolute Dimension
Display 1280 x 1024, image display 8000 x 8000
256 levels of color or black/white
Source Energy 6 MeV Linac
Source Output 850 R/min @ 1m max.










© 2008 HESCO. All Rights Reserved. 